This page lists the planned entities of CeilSense Pro, grouped by function and radar configuration. Which entities you will see depends on the radar in your device and the firmware on it.
Names can change at release. The firmware for the final CeilSense Pro is not written yet. The names on this page come from an earlier prototype and can change at release. Entity IDs in Home Assistant start with your device name, so they can differ per installation.
The Category column shows where Home Assistant will list the entity on the device page: Regular for normal sensors and controls, Config for settings and Diagnostic for technical information. Where several numbered entities work the same way, the table uses N for the number.
Every CeilSense Pro
Light
Entity
Type
Category
Description
Illuminance
Sensor
Regular
Light level in lux from the Vishay VEML6030
Whether a separate corrected value follows, as on CeilSense V2, is decided with the firmware.
CO2, Temperature and Humidity (SCD41)
Entity
Type
Category
Description
SCD41 CO2
Sensor
Regular
CO2 in ppm. New value every 30 seconds.
SCD41 Temperature
Sensor
Regular
Temperature in °C. New value every 30 seconds.
SCD41 Humidity
Sensor
Regular
Relative humidity in %. New value every 30 seconds.
SCD41 Extra Temperature Offset
Number
Config
Correction in °C, -20 to +20, step 0.1. Added on top of the factory correction and kept after a restart.
SCD41 Humidity Offset
Number
Config
Correction in %, -20 to +20, step 0.1, default 0. Kept after a restart.
SCD41 Calibrate Fresh Air
Button
Config
Sets the CO2 reading to 426 ppm. Only press it in fresh air: see Calibration.
Temperature and Humidity (SHT45)
The prototype firmware has no SHT45 entities yet. Their names follow with release firmware.
VOC and NOx (SGP41)
These values are indices, not ppm.
Entity
Type
Category
Description
SGP41 VOC Index
Sensor
Regular
VOC index from 1 to 500
SGP41 NOx Index
Sensor
Regular
NOx index from 1 to 500
Air Pressure
Entity
Type
Category
Description
BMP388 Pressure
Sensor
Regular
Air pressure from the Bosch BMP388
BMP388 Temperature
Sensor
Regular
Temperature inside the device, not room temperature
LED Ring and Buzzer
Entity
Type
Category
Description
LED Ring
Light
Regular
Color, brightness and effect. Off by default. The list of effects follows with release firmware.
Buzzer Test
Button
Diagnostic
Plays a short melody on the buzzer
Speaker and Microphone
Entity
Type
Category
Description
Speaker
Media player
Regular
Plays music, MP3 files and spoken announcements through Home Assistant
The prototype firmware has no microphone entities yet. They follow with release firmware.
Optical Smoke Sensing
Experimental, and not a safety function. See Optical Smoke Sensing. Entities marked disabled are disabled by default.
Entity
Type
Category
Description
ADPD188BI Smoke Alert
Binary sensor
Regular
On when four consecutive candidates were seen. Off only means this measurement has no alert.
ADPD188BI Smoke Index
Sensor
Regular
Relative rise above the baseline in %. Not a concentration. Stays at 0 during the warm-up.
ADPD188BI Blue
Sensor
Regular
Raw reading of the blue channel
ADPD188BI Infrared
Sensor
Regular
Raw reading of the infrared channel
Smoke Siren Enabled
Switch
Config
Allows the siren on the buzzer. Off by default, and it keeps your setting after a restart.
Remote Smoke Alarm
Switch
Regular
Lets Home Assistant start the siren and strobe of this unit. Not restored after a restart.
Smoke Alarm Silence
Button
Regular
Mutes an active siren for 10 minutes
Smoke Test
Button
Diagnostic
Runs a self-test of the sensor
Smoke Self Test Result
Text sensor
Diagnostic
PASS or FAIL from the last Smoke Test
ADPD188BI Sensor Problem
Binary sensor
Diagnostic
On after a setup failure or failed reads
ADPD188BI Baseline Ready
Binary sensor
Diagnostic
On when the warm-up is done
ADPD188BI Measurement Stable
Binary sensor
Diagnostic
On when the measuring window is valid
ADPD188BI Alarm Candidate
Binary sensor
Diagnostic
On while a window counts as a candidate
ADPD188BI eFuse Calibration Ready
Binary sensor
Diagnostic
On when the factory calibration of the sensor has been read
ADPD188BI Blue Delta
Sensor
Diagnostic
Rise of the blue channel above its baseline
ADPD188BI Infrared Delta
Sensor
Diagnostic
Rise of the infrared channel above its baseline
ADPD188BI Blue Baseline
Sensor
Diagnostic
Baseline of the blue channel, disabled
ADPD188BI Infrared Baseline
Sensor
Diagnostic
Baseline of the infrared channel, disabled
ADPD188BI Blue IR Ratio
Sensor
Diagnostic
Ratio between the blue and infrared channel, disabled
ADPD188BI Device ID
Sensor
Diagnostic
Identification of the sensor, disabled
ADPD188BI eFuse Module ID
Sensor
Diagnostic
Module number of the sensor, disabled
ADPD188BI Blue Calibration Gain
Sensor
Diagnostic
Factory calibration of the blue channel, disabled
ADPD188BI Infrared Calibration Gain
Sensor
Diagnostic
Factory calibration of the infrared channel, disabled
Device
Entity
Type
Category
Description
Restart Device
Button
Config
Restarts the device. The optical smoke sensing then starts its warm-up again.
Factory Reset
Button
Config
Resets the device to factory settings. Disabled by default.
Software Version
Text sensor
Regular
Firmware version
Hardware Version
Text sensor
Regular
Hardware version
Network Variant
Text sensor
Regular
WiFi or Ethernet build
CPU Temperature
Sensor
Diagnostic
Temperature of the processor
Device Info
Text sensor
Diagnostic
Technical information about the device
ESP Reset Reason
Text sensor
Diagnostic
Reason for the last restart. Disabled by default.
Network
All of these are disabled by default.
Entity
Type
Category
Description
WiFi IP Address
Text sensor
Diagnostic
IP address of the device. WiFi firmware only.
WiFi MAC
Text sensor
Diagnostic
Network address of the WiFi connection. WiFi firmware only.
WiFi Signal
Sensor
Diagnostic
Strength of the WiFi signal. WiFi firmware only.
Ethernet IP Address
Text sensor
Diagnostic
IP address of the device. Ethernet firmware only.
Ethernet MAC
Text sensor
Diagnostic
Network address of the Ethernet connection. Ethernet firmware only.
With LD2412 + LD2450
Combined Presence
Entity
Type
Category
Description
Presence
Binary sensor
Regular
On when either radar sees someone. Use this one for most automations.
LD2412
Entity
Type
Category
Description
LD2412 Presence
Binary sensor
Regular
On when the LD2412 sees a moving or still target
LD2412 Moving Target
Binary sensor
Regular
On when a moving target is detected
LD2412 Still Target
Binary sensor
Regular
On when a still target is detected
LD2412 Moving Distance
Sensor
Regular
Distance to the moving target
LD2412 Still Distance
Sensor
Regular
Distance to the still target
LD2412 Moving Energy
Sensor
Regular
Signal strength of the moving target
LD2412 Still Energy
Sensor
Regular
Signal strength of the still target
LD2412 Detection Distance
Sensor
Regular
Distance to the closest detected target
LD2412 Light
Sensor
Diagnostic
Light value reported by the radar module
LD2412 Dynamic Background Correction
Binary sensor
Diagnostic
On while the background correction runs
LD2412 Firmware Version
Text sensor
Diagnostic
Firmware of the radar module. Empty means the module is not seen.
LD2412 MAC
Text sensor
Diagnostic
Bluetooth address of the radar module
LD2412 Presence Timeout
Number
Config
Seconds that presence stays on after the last detection
LD2412 Minimum Distance Gate
Number
Config
Closest gate used for detection, 1 to 12
LD2412 Maximum Distance Gate
Number
Config
Furthest gate used for detection, 2 to 13
LD2412 Distance Resolution
Select
Config
Length of each gate: 0.2 m, 0.5 m or 0.75 m
LD2412 Light Threshold
Number
Config
Threshold for the radar's own light function
LD2412 Light Function
Select
Config
Light function of the radar: off, below or above
LD2412 Engineering Mode
Switch
Config
Engineering mode of the radar. Not needed in normal use.
LD2412 Bluetooth
Switch
Config
Bluetooth of the radar module, for the HLK Radar Tool app
LD2412 Start Dynamic Background Correction
Button
Diagnostic
Starts the background correction. The room must be empty.
LD2412 Restart
Button
Diagnostic
Restarts the radar module only
LD2412 Query Parameters
Button
Diagnostic
Reads the settings from the radar again
LD2412 Factory Reset
Button
Diagnostic
Resets the radar module to factory settings
LD2450
Entity
Type
Category
Description
LD2450 Presence
Binary sensor
Regular
On when the LD2450 sees a target
LD2450 Moving Target
Binary sensor
Regular
On when a moving target is detected
LD2450 Still Target
Binary sensor
Regular
On when a still target is detected
LD2450 Target Count
Sensor
Regular
Number of targets
LD2450 Moving Target Count
Sensor
Regular
Number of moving targets
LD2450 Still Target Count
Sensor
Regular
Number of still targets
LD2450 Target N Distance
Sensor
Regular
Distance to the target. N is 1 to 3.
LD2450 Zone N Target Count
Sensor
Regular
Number of targets inside the zone. N is 1 to 3.
LD2450 Target N X
Sensor
Diagnostic
X position in mm
LD2450 Target N Y
Sensor
Diagnostic
Y position in mm
LD2450 Target N Speed
Sensor
Diagnostic
Speed of the target
LD2450 Target N Angle
Sensor
Diagnostic
Angle to the target
LD2450 Target N Direction
Text sensor
Diagnostic
Direction of the target
LD2450 Target N Resolution
Sensor
Diagnostic
Distance resolution of the target
LD2450 Firmware Version
Text sensor
Diagnostic
Firmware of the radar module. Empty means the module is not seen.
LD2450 MAC
Text sensor
Diagnostic
Bluetooth address of the radar module
LD2450 Presence Timeout
Number
Config
Seconds that presence stays on after the last detection
LD2450 Zone Type
Select
Config
How the zones work: Disabled, Detection or Filter
LD2450 Zone N X1, Y1, X2, Y2
Number
Config
Corners of the zone in mm. N is 1 to 3.
LD2450 Multi Target Tracking
Switch
Config
Tracks several people instead of one
LD2450 Bluetooth
Switch
Config
Bluetooth of the radar module, for the HLK Radar Tool app
LD2450 Baud Rate
Select
Config
Speed of the connection to the radar. Leave this as it is.
LD2450 Restart
Button
Diagnostic
Restarts the radar module only
LD2450 Factory Reset
Button
Diagnostic
Resets the radar module to factory settings
With LD2460
Firmware for the LD2460 on CeilSense Pro is planned. The names below are those of the LD2460 component that SmartHomeShop maintains.
Presence and Targets
Entity
Type
Category
Description
Presence
Binary sensor
Regular
Follows Tracking Presence. Use this one for most automations.
Tracking Presence
Binary sensor
Regular
On when the LD2460 sees someone
Tracking Target Count
Sensor
Regular
Number of targets
Tracking Targets
Text sensor
Regular
Text summary of the targets
Tracking Target N X
Sensor
Regular
X position in meters. N is 1 to 5.
Tracking Target N Y
Sensor
Regular
Y position in meters
Tracking Target N Distance
Sensor
Regular
Distance to the target in meters
Tracking Target N Angle
Sensor
Regular
Angle to the target in degrees
Radar Settings
Entity
Type
Category
Description
Tracking Radar Installation Mode
Select
Config
side or top. The firmware sets top for ceiling mounting.
Tracking Radar Detection Distance
Number
Config
Distance of the detection sector in meters
Tracking Radar Detection Start Angle
Number
Config
Start of the detection sector in degrees
Tracking Radar Detection End Angle
Number
Config
End of the detection sector in degrees
Tracking Radar Installation Height
Number
Config
For wall mounting. Not needed on the ceiling.
Tracking Radar Installation Angle
Number
Config
For wall mounting. Not needed on the ceiling.
Tracking Radar Firmware
Text sensor
Diagnostic
Firmware of the radar module. Empty means the module is not seen.
Tracking Radar Installation Mode
Text sensor
Diagnostic
The mode the radar reports
Tracking Raw UART
Text sensor
Diagnostic
Raw data for diagnosis. Disabled by default.
Tracking UART Bytes
Sensor
Diagnostic
Byte counter for diagnosis. Disabled by default.
Room Designer Zones
These entities belong to the zones you draw in the Room Designer.
Entity
Type
Category
Description
Polygon Zone N Presence
Binary sensor
Regular
On when someone is inside the zone. N is 1 to 4.
Polygon Zone N Target Count
Sensor
Regular
Number of targets inside the zone. N is 1 to 4.
People Count
Sensor
Regular
Running count of people in the room, based on entry lines
Last Crossing Direction
Text sensor
Regular
Direction of the last crossing of an entry line
Polygon Zones Enabled
Switch
Config
Turns the zones on or off. On by default.
Polygon Zone N
Text
Config
Shape of the zone. The Room Designer writes this. N is 1 to 4.
Polygon Exclusion N
Text
Config
Area where targets are ignored. The Room Designer writes this. N is 1 or 2.
Entry Line N
Text
Config
Line used for counting people. The Room Designer writes this. N is 1 or 2.
Reset People Count
Button
Config
Sets the people count back to zero
The LD2460 build also has a set of diagnostic entities starting with Radar, such as Radar Model and Radar Mounting Mode. They tell the Room Designer how the radar is mounted, and you do not need to change them.
With LD6002B
Firmware for the LD6002B on CeilSense Pro is not finished, so its entity names are not final and are not listed here. Expect presence per target, detection areas, target and point counts, X, Y and Z per target in meters, and settings for installation mode, sensitivity and trigger speed.